home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / text / 07411bsc.txt < prev    next >
Text File  |  1998-06-10  |  9KB  |  243 lines

  1.                          SECTION 07411
  2.  
  3.                     GALVALUME(R) ROOF PANELS
  4. NOTE ** This section is based on preformed metal roofing
  5.         that is manufactured from Galvalume(R) sheet, as
  6.         produced by Bethlehem Steel Corporation, located at
  7.         the following address:
  8. NOTE **     Bethlehem, Pennsylvania 18016-7699
  9. NOTE **     Tel. (800) 352-5700, extension 400.
  10. NOTE **
  11. NOTE ** Galvalume(R) sheet is a metallic coated sheet
  12.         steel.  Its optimum 55% aluminum-zinc alloy coating
  13.         provides exceptional long-term durability.  In
  14.         addition, in combination with today's high
  15.         performance paint systems, prepainted Galvalume(R)
  16.         sheet provides this outstanding long-term
  17.         performance with a wide range of aesthetic options.
  18. NOTE **
  19. NOTE ** Galvalume(R) is a registered trademark of BIEC
  20.         International, Inc.
  21. NOTE **
  22. NOTE ** SECTION 07411 - GALVALUME ROOF PANELS, Copyright
  23.         1997, The Architect's Catalog, Inc.
  24.  
  25.  
  26. PART 1  GENERAL
  27.  
  28. 1.1 SECTION INCLUDES
  29. NOTE ** Edit items below as required for project.
  30.  
  31.     A.  Labor, materials, tools, equipment, and services for
  32.         preformed Galvalume(R) roofing, including roof panels,
  33.         flashings and all other accessories necessary for a
  34.         sound, secure and complete installation.
  35.  
  36.     B.  Coordination with related work.
  37.  
  38. 1.2 RELATED SECTIONS
  39. NOTE ** Delete any sections below not relevant to this
  40.         project; add others as required.
  41.  
  42.     A.  Section 05120 - Structural Steel.
  43.  
  44.     B.  Section 06100 - Rough Carpentry:  Framing and Sheathing.
  45.  
  46.     C.  Section 06150 - Wood Decking.
  47.  
  48.     D.  Section 07210 - Building Insulation.
  49.  
  50.     E.  Section 07620 - Sheet Metal Flashing and Trim.
  51.  
  52.     F.  Section 07900 - Joint Sealers.
  53.  
  54. 1.3 REFERENCES
  55. NOTE ** Add any references to the list below that are
  56.         included in text you have added to the section.
  57.  
  58.     A.  ASTM A 792/A 792M - Standard Specification for Steel
  59.         Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip
  60.         Process, General Requirements.
  61.  
  62. 1.4 SUBMITTALS
  63.  
  64.     A.  Submit under provisions of Section 01300.
  65.  
  66.     B.  Product Data:  Submit manufacturer's product
  67.         specifications, standard details, installation
  68.         instructions and general recommendations, as applicable
  69.         to materials and finishes for each component and for
  70.         complete roofing installation.
  71.  
  72.     C.  Shop Drawings:  Submit complete shop drawings and
  73.         erection details showing methods of erection, elevations
  74.         and plans of roof panels, sections and details,
  75.         anticipated loads, flashings and all other accessories,
  76.         interfaces with all related work of other trades, and
  77.         proposed identification of component parts and their
  78.         finishes.
  79.  
  80.     D.  Selection Samples:  Submit color chips for selection of
  81.         finishes.
  82.  
  83.     E.  Verification Samples:  Submit one sample of roof panel,
  84.         including clips and battens if applicable.  Submit two
  85.         color chip samples in color selected by Architect.
  86.  
  87.     F.  Certifications:  Submit certification that roofing
  88.         assembly meets specified loading requirements and has
  89.         been pretested to provide specified resistance to wind
  90.         uplift, and air and water infiltration.
  91.  
  92. 1.5 QUALITY ASSURANCE
  93.  
  94.     A.  Manufacturer:  Minimum __ years experience in
  95.         manufacturing roof panels similar to those required for
  96.         this project.
  97.  
  98.     B.  Installer:  Minimum __ years experience in installing
  99.         roof panels similar to those required for this project.
  100.  
  101.     C.  Field Measurements:  Where possible, take field
  102.         measurements of structural framing and substrate to
  103.         receive the roofing, prior to fabrication of roof panels.
  104.  
  105. 1.6 DELIVERY, STORAGE, AND HANDLING
  106.  
  107.     A.  Delivery:  Deliver roof panels to project site packaged
  108.         to provide protection against transportation damage and
  109.         adverse weather.  Inspect roof panels upon arrival at
  110.         site.  Notify manufacturer of any damaged or stained
  111.         material.
  112.  
  113.     B.  Storage:  Store all material and accessories above ground
  114.         on well skidded platforms.  Elevate one end of each skid
  115.         to allow for moisture run-off.  Store under waterproof
  116.         covering.  Provide proper ventilation to prevent
  117.         condensation build-up between each roof panel.
  118.  
  119.     C.  Handling:  Exercise extreme care in unloading, storing
  120.         and erecting roof panels to prevent bending, warping,
  121.         twisting, and surface damage.
  122.  
  123. 1.7 WARRANTY
  124.  
  125.     A.  Material Warranty:  Provide warranty issued by
  126.         manufacturer to cover roof panel base metal against
  127.         rupture, structural failure, or perforation due to
  128.         exposure to normal atmospheric corrosion for a period of
  129.         20 years and 6 months.
  130. NOTE ** If warranty requirements below are retained, verify
  131.         they are available from selected manufacturer.
  132.         Include required term of each warranty.
  133.  
  134.     B.  Weathertightness Warranty:  Provide warranty issued by
  135.         installer to cover roofing against leaks arising out of
  136.         or caused by ordinary wear and tear under normal weather
  137.         and atmospheric conditions for a period of __ years.
  138.  
  139.     C.  Finish Warranty:  Provide manufacturer's warranty to
  140.         cover roof panel finish against cracking, checking,
  141.         blistering, peeling, flaking, chipping, chalking, and
  142.         fading under normal atmospheric conditions for a period
  143.         of __ years.
  144.  
  145.  
  146. PART 2  PRODUCTS
  147.  
  148. 2.1 MANUFACTURERS
  149.  
  150.     A.  Material:  Provide Galvalume(R) sheet as manufactured by
  151.         Bethlehem Steel Corporation; Bethlehem PA 18016-7699;
  152.         ASD. Tel. (800) 352-5700, extension 400.
  153. NOTE ** Contact Bethlehem for a current "Suppliers of
  154.         Galvalume(R) Sheet Roofing Components"; Booklet
  155.         #2879.
  156.  
  157.     B.  Roofing:  Provide preformed Galvalume(R) roof panels,
  158.         flashings and accessories from one of the following
  159.         manufacturers:
  160.         1.  Manufacturer No. 1:  ____________________________.
  161.         2.  Manufacturer No. 2:  ____________________________.
  162.         3.  Manufacturer No. 3:  ____________________________.
  163.  
  164.     C.  Substitutions are not acceptable.
  165. NOTE ** Delete paragraph above or below;  edit as required
  166.         for project.
  167.  
  168.     D.  Submit requests for substitutions in accordance with
  169.         provisions of Section 01600.
  170.  
  171. 2.2 MATERIALS
  172.  
  173.     A.  Roof Panels, Flashings, and Accessories:  Structural
  174.         quality aluminum-zinc alloy-coated steel sheet
  175.         (Galvalume(R)), complying with ASTM A 792 and with
  176.         coating weight, grade and thickness to suit
  177.         manufacturer's standards.
  178. NOTE ** Retain paragraph below only if prefinished roofing
  179.         is required.  Select paint system and color from
  180.         manufacturer's standard offerings.
  181.  
  182.     B.  Finish:  Apply paint system by a pre-approved coil coater
  183.         in accordance with Bethlehem's "Process Specification for
  184.         Prepainted Galvalume(R) Sheet."
  185.         1.  Paint System:  ________________________________.
  186.         2.  Color:  ____________________________.
  187.         3.  Color:  As selected by Architect from manufacturer's
  188.             standards.
  189.  
  190. 2.3 FABRICATION
  191.  
  192.     A.  Roll-form continuous roof panels, as detailed on approved
  193.         shop drawings, in lengths up to manufacturer's maximum
  194.         standard lengths.
  195.  
  196.     B.  Fabricate trim, flashing and accessories, as detailed on
  197.         approved shop drawings.
  198.  
  199.     C.  Fabricate trim and flashing from same material as panel.
  200.  
  201.  
  202. PART 3  EXECUTION
  203.  
  204. 3.1 EXAMINATION
  205.  
  206.     A.  Verify that substrates and adjacent work are ready to
  207.         receive work of this section.  Do not proceed until
  208.         unsatisfactory conditions have been corrected.
  209.  
  210. 3.2 INSTALLATION
  211.  
  212.     A.  Install panels so they are weathertight, allowing for
  213.         expansion and contraction.
  214.  
  215.     B.  Install panels in accordance with manufacturer's
  216.         instructions and approved shop drawings.
  217.  
  218.     C.  Install panels plumb, level, and straight, with seams and
  219.         ribs/battens parallel, conforming to the design as
  220.         indicated.
  221.  
  222. 3.3 ADJUSTING AND CLEANING
  223.  
  224.     A.  Dispose of excess materials and remove debris from site.
  225.  
  226.     B.  Clean work in accordance with recommendations of roofing
  227.         panel manufacturer.
  228.  
  229.     C.  Touch up minor scratches and abrasions with paint
  230.         provided or approved by panel manufacturer.
  231.  
  232.     D.  Protect work against damage.  Replace any work that
  233.         becomes damaged prior to final acceptance.
  234. NOTE ** DISCLAIMER:  The information presented in this
  235.         document is for illustrative purposes only.
  236.         Bethlehem Steel Corporation assumes no
  237.         responsibility for its use.  Anyone relying upon or
  238.         making use of this information does so at his own
  239.         risk and assumes any and all liability or other
  240.         consequences resulting therefrom.
  241.  
  242.                          END OF SECTION
  243.